Follett WU-0105-AC

Harvest Rate

72lb/day

Energy Use

8.34kWh/100 lb

Water Use

16.5gal/100 lb

Refrigerant

R-290

GWP 3 · Lower

Scotsman GEMU09090

Harvest Rate

73lb/day

Energy Use

7.48kWh/100 lb

Water Use

12gal/100 lb

Refrigerant

R-290

GWP 3 · Lower

Key differences

Scotsman GEMU09090 is 10% more efficient at 7.48 kWh/100 lb versus 8.34 kWh/100 lb for the Follett WU-0105-AC. The Scotsman GEMU09090 is larger at 73 lb/day versus 72 lb/day. Overall, the Follett WU-0105-AC sits higher in the category, ranking above 80% of certified commercial ice machines.

Production

SpecFollettScotsman
Harvest Rate(lb/day)7273
Ice TypeBatchContinuous
Equipment TypeSelf Contained UnitSelf Contained Unit
Ice Hardness Factor10079.54

Efficiency

SpecFollettScotsman
Energy Use(kWh/100 lb)8.347.48
Potable Water Use(gal/100 lb)16.512

Refrigerant

SpecFollettScotsman
TypeR-290R-290
GWP RatingR-290 (GWP:3 | Lower GWP)R-290 (GWP:3 | Lower GWP)

Connectivity

SpecFollettScotsman
ConnectedNoNo

More comparisons