SpecDirectory

1HVAC ACIQ-24-HP32vsACIQ B5H0V24*K*AAA*

Side-by-side heat pump comparison

1HVAC ACIQ-24-HP32

SEER2

18BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

24000BTU/hr

Cold Climate

Yes

Cold climate certified

ACIQ B5H0V24*K*AAA*

SEER2

15.5–17.5BTU/Wh

HSPF2

8.5–9BTU/Wh

Cooling Capacity

22400–24200BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

1HVAC ACIQ-24-HP32 is 3% more efficient at 18.0 BTU/Wh versus 17.5 BTU/Wh for the ACIQ B5H0V24*K*AAA*. The ACIQ B5H0V24*K*AAA* is larger at 24200 BTU/hr versus 24000 BTU/hr. ACIQ B5H0V24*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

Spec1HVACACIQ
SEER2 (best combination)(BTU/Wh)1817.5
SEER2 (worst combination)(BTU/Wh)1815.5
HSPF2 (best combination)(BTU/Wh)109
HSPF2 (worst combination)(BTU/Wh)108.5
EER2 (best combination)(BTU/Wh)12.510.5
COP at 5 °F22.02

Capacity

Spec1HVACACIQ
Cooling Capacity (max)(BTU/hr)2400024200
Cooling Capacity (min)(BTU/hr)2400022400
Heating at 47 °F(BTU/hr)2500024600
Heating at 17 °F(BTU/hr)2060020800
Heating at 5 °F(BTU/hr)2500017300

Configuration

Spec1HVACACIQ
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesR32 Extreme Heat UnitaryDeluxe 20 VS Heat Pump
Indoor-Unit Combinations Rated186

Refrigerant

Spec1HVACACIQ
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons