SpecDirectory

1HVAC ACIQ-60-EHPDvsCarrier 27VNA154A*030*

Side-by-side heat pump comparison

1HVAC ACIQ-60-EHPD

SEER2

15.2BTU/Wh

HSPF2

8.4BTU/Wh

Cooling Capacity

54000BTU/hr

Cold Climate

Yes

Cold climate certified

Carrier 27VNA154A*030*

SEER2

17–21.2BTU/Wh

HSPF2

8.1–12BTU/Wh

Cooling Capacity

47500–53500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Carrier 27VNA154A*030* is 28% more efficient at 21.2 BTU/Wh versus 15.2 BTU/Wh for the 1HVAC ACIQ-60-EHPD. The 1HVAC ACIQ-60-EHPD is larger at 54000 BTU/hr versus 53500 BTU/hr. Overall, the Carrier 27VNA154A*030* sits higher in the category, ranking above 93% of certified air-source heat pumps.

Efficiency

Spec1HVACCarrier
SEER2 (best combination)(BTU/Wh)15.221.2
SEER2 (worst combination)(BTU/Wh)15.217
HSPF2 (best combination)(BTU/Wh)8.412
HSPF2 (worst combination)(BTU/Wh)8.48.1
EER2 (best combination)(BTU/Wh)8.613.5
COP at 5 °F1.802.10

Capacity

Spec1HVACCarrier
Cooling Capacity (max)(BTU/hr)5400053500
Cooling Capacity (min)(BTU/hr)5400047500
Heating at 47 °F(BTU/hr)5400055000
Heating at 17 °F(BTU/hr)3600052000
Heating at 5 °F(BTU/hr)3800054000

Configuration

Spec1HVACCarrier
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesACIQ SeriesInfinity 21 VS Cold Climate Heat Pump
Indoor-Unit Combinations Rated1153

Refrigerant

Spec1HVACCarrier
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons