SpecDirectory

1HVAC ACIQ-60ZPL-HP230BvsAC PRO SPHP-B-60VBB

Side-by-side heat pump comparison

1HVAC ACIQ-60ZPL-HP230B

SEER2

15.8–17.3BTU/Wh

HSPF2

9.5–10.2BTU/Wh

Cooling Capacity

55000BTU/hr

Cold Climate

Yes

Cold climate certified

AC PRO SPHP-B-60VBB

SEER2

17–17.5BTU/Wh

HSPF2

8.6–9BTU/Wh

Cooling Capacity

47500–55500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 17.3 vs 17.5 BTU/Wh. The AC PRO SPHP-B-60VBB is larger at 55500 BTU/hr versus 55000 BTU/hr. AC PRO SPHP-B-60VBB uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

Spec1HVACAC PRO
SEER2 (best combination)(BTU/Wh)17.317.5
SEER2 (worst combination)(BTU/Wh)15.817
HSPF2 (best combination)(BTU/Wh)10.29
HSPF2 (worst combination)(BTU/Wh)9.58.6
EER2 (best combination)(BTU/Wh)9.411.3
COP at 5 °F1.972.10

Capacity

Spec1HVACAC PRO
Cooling Capacity (max)(BTU/hr)5500055500
Cooling Capacity (min)(BTU/hr)5500047500
Heating at 47 °F(BTU/hr)6000057000
Heating at 17 °F(BTU/hr)4000042000
Heating at 5 °F(BTU/hr)5650042500

Configuration

Spec1HVACAC PRO
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesACIQB-Series
Indoor-Unit Combinations Rated22

Refrigerant

Spec1HVACAC PRO
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons