1HVAC ACIQ-PHH1760000K000V

SEER2

17BTU/Wh

HSPF2

8.3BTU/Wh

Cooling Capacity

56000BTU/hr

Cold Climate

Yes

Cold climate certified

Thermal Zone TZID60H520ZC

SEER2

17–17.5BTU/Wh

HSPF2

8.6–9BTU/Wh

Cooling Capacity

47500–55500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Thermal Zone TZID60H520ZC is 3% more efficient at 17.5 BTU/Wh versus 17.0 BTU/Wh for the 1HVAC ACIQ-PHH1760000K000V. The 1HVAC ACIQ-PHH1760000K000V is larger at 56000 BTU/hr versus 55500 BTU/hr. Thermal Zone TZID60H520ZC uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

Spec1HVACThermal Zone
SEER2 (best combination)(BTU/Wh)1717.5
SEER2 (worst combination)(BTU/Wh)1717
HSPF2 (best combination)(BTU/Wh)8.39
HSPF2 (worst combination)(BTU/Wh)8.38.6
EER2 (best combination)(BTU/Wh)10.611.3
COP at 5 °F1.802.10

Capacity

Spec1HVACThermal Zone
Cooling Capacity (max)(BTU/hr)5600055500
Cooling Capacity (min)(BTU/hr)5600047500
Heating at 47 °F(BTU/hr)5700057000
Heating at 17 °F(BTU/hr)3700042000
Heating at 5 °F(BTU/hr)4500042500

Configuration

Spec1HVACThermal Zone
Product TypeHP - Single PackageHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesExtreme Heat Inverter RooftopTZID60H520ZC
Indoor-Unit Combinations Rated12

Refrigerant

Spec1HVACThermal Zone
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)