SpecDirectory

AC PRO AOD30-30HFN1-MS0WvsAirquest N5H5S30*K*AAA*

Side-by-side heat pump comparison

AC PRO AOD30-30HFN1-MS0W

SEER2

20BTU/Wh

HSPF2

9.2BTU/Wh

Cooling Capacity

30000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Airquest N5H5S30*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

27600–30200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

AC PRO AOD30-30HFN1-MS0W is 24% more efficient at 20.0 BTU/Wh versus 15.2 BTU/Wh for the Airquest N5H5S30*K*AAA*. The Airquest N5H5S30*K*AAA* is larger at 30200 BTU/hr versus 30000 BTU/hr. Airquest N5H5S30*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the AC PRO AOD30-30HFN1-MS0W sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecAC PROAirquest
SEER2 (best combination)(BTU/Wh)2015.2
SEER2 (worst combination)(BTU/Wh)2015.2
HSPF2 (best combination)(BTU/Wh)9.28.1
HSPF2 (worst combination)(BTU/Wh)9.27.8
EER2 (best combination)(BTU/Wh)11.512.5
COP at 5 °F1.952.26

Capacity

SpecAC PROAirquest
Cooling Capacity (max)(BTU/hr)3000030200
Cooling Capacity (min)(BTU/hr)3000027600
Heating at 47 °F(BTU/hr)3000029000
Heating at 17 °F(BTU/hr)1900017800
Heating at 5 °F(BTU/hr)1750013900

Configuration

SpecAC PROAirquest
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesAOD SeriesPERFORMANCE 16 SEER2 HP
Indoor-Unit Combinations Rated16

Refrigerant

SpecAC PROAirquest
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons