SpecDirectory

AC PRO AOX230-09HFN1-MW5WvsAireForce DXH09PSK3IH

Side-by-side heat pump comparison

AC PRO AOX230-09HFN1-MW5W

SEER2

19.2–25.5BTU/Wh

HSPF2

10–12.3BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

AireForce DXH09PSK3IH

SEER2

24–26BTU/Wh

HSPF2

9.2–10.4BTU/Wh

Cooling Capacity

9100BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 25.5 vs 26.0 BTU/Wh. The AireForce DXH09PSK3IH is larger at 9100 BTU/hr versus 9000 BTU/hr. AireForce DXH09PSK3IH uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecAC PROAireForce
SEER2 (best combination)(BTU/Wh)25.526
SEER2 (worst combination)(BTU/Wh)19.224
HSPF2 (best combination)(BTU/Wh)12.310.4
HSPF2 (worst combination)(BTU/Wh)109.2
EER2 (best combination)(BTU/Wh)1515
COP at 5 °F2.341.94

Capacity

SpecAC PROAireForce
Cooling Capacity (max)(BTU/hr)90009100
Cooling Capacity (min)(BTU/hr)90009100
Heating at 47 °F(BTU/hr)1100010500
Heating at 17 °F(BTU/hr)850011000
Heating at 5 °F(BTU/hr)80009500

Configuration

SpecAC PROAireForce
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesA seriesMultizone Indoors Eight-way Compact Cassettes
Indoor-Unit Combinations Rated42

Refrigerant

SpecAC PROAireForce
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons