SpecDirectory

AC PRO MHPC-D-036BMCvsAmerican Standard 5A6V0X36A1

Side-by-side heat pump comparison

AC PRO MHPC-D-036BMC

SEER2

18–21BTU/Wh

HSPF2

8.1–10BTU/Wh

Cooling Capacity

36000BTU/hr

Cold Climate

Yes

Cold climate certified

American Standard 5A6V0X36A1

SEER2

19.2–21BTU/Wh

HSPF2

9.4–10.5BTU/Wh

Cooling Capacity

34600–36200BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

The American Standard 5A6V0X36A1 is larger at 36200 BTU/hr versus 36000 BTU/hr. American Standard 5A6V0X36A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecAC PROAmerican Standard
SEER2 (best combination)(BTU/Wh)2121
SEER2 (worst combination)(BTU/Wh)1819.2
HSPF2 (best combination)(BTU/Wh)1010.5
HSPF2 (worst combination)(BTU/Wh)8.19.4
EER2 (best combination)(BTU/Wh)1213
COP at 5 °F2.102.24

Capacity

SpecAC PROAmerican Standard
Cooling Capacity (max)(BTU/hr)3600036200
Cooling Capacity (min)(BTU/hr)3600034600
Heating at 47 °F(BTU/hr)3600033200
Heating at 17 °F(BTU/hr)3600031600
Heating at 5 °F(BTU/hr)3600025400

Configuration

SpecAC PROAmerican Standard
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesD SeriesPLATINUM 20
Indoor-Unit Combinations Rated3113

Refrigerant

SpecAC PROAmerican Standard
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)