SpecDirectory

ACD UHD09KCH38SB-OvsAireForce DXH09PSK3IH

Side-by-side heat pump comparison

ACD UHD09KCH38SB-O

SEER2

27BTU/Wh

HSPF2

11BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

AireForce DXH09PSK3IH

SEER2

24–26BTU/Wh

HSPF2

9.2–10.4BTU/Wh

Cooling Capacity

9100BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

ACD UHD09KCH38SB-O is 4% more efficient at 27.0 BTU/Wh versus 26.0 BTU/Wh for the AireForce DXH09PSK3IH. The AireForce DXH09PSK3IH is larger at 9100 BTU/hr versus 9000 BTU/hr. AireForce DXH09PSK3IH uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecACDAireForce
SEER2 (best combination)(BTU/Wh)2726
SEER2 (worst combination)(BTU/Wh)2724
HSPF2 (best combination)(BTU/Wh)1110.4
HSPF2 (worst combination)(BTU/Wh)119.2
EER2 (best combination)(BTU/Wh)16.615
COP at 5 °F1.911.94

Capacity

SpecACDAireForce
Cooling Capacity (max)(BTU/hr)90009100
Cooling Capacity (min)(BTU/hr)90009100
Heating at 47 °F(BTU/hr)900010500
Heating at 17 °F(BTU/hr)820011000
Heating at 5 °F(BTU/hr)130009500

Configuration

SpecACDAireForce
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesLOMO 38SEERMultizone Indoors Eight-way Compact Cassettes
Indoor-Unit Combinations Rated22

Refrigerant

SpecACDAireForce
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons