SpecDirectory

ACIQ ACIQ-18Z-E-HH-M2vsHaier 1U18EH2HE**

Side-by-side heat pump comparison

ACIQ ACIQ-18Z-E-HH-M2

SEER2

20.5–23.3BTU/Wh

HSPF2

9.8–11BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Haier 1U18EH2HE**

SEER2

23BTU/Wh

HSPF2

12BTU/Wh

Cooling Capacity

17800BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 23.3 vs 23.0 BTU/Wh. The ACIQ ACIQ-18Z-E-HH-M2 is larger at 18000 BTU/hr versus 17800 BTU/hr. ACIQ ACIQ-18Z-E-HH-M2 uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088). Overall, the ACIQ ACIQ-18Z-E-HH-M2 sits higher in the category, ranking above 81% of certified air-source heat pumps.

Efficiency

SpecACIQHaier
SEER2 (best combination)(BTU/Wh)23.323
SEER2 (worst combination)(BTU/Wh)20.523
HSPF2 (best combination)(BTU/Wh)1112
HSPF2 (worst combination)(BTU/Wh)9.812
EER2 (best combination)(BTU/Wh)12.513
COP at 5 °F21.90

Capacity

SpecACIQHaier
Cooling Capacity (max)(BTU/hr)1800017800
Cooling Capacity (min)(BTU/hr)1800017800
Heating at 47 °F(BTU/hr)1800020000
Heating at 17 °F(BTU/hr)2200015300
Heating at 5 °F(BTU/hr)2180018000

Configuration

SpecACIQHaier
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesMulti-spilt seriesArctic
Indoor-Unit Combinations Rated31

Refrigerant

SpecACIQHaier
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)

More comparisons