SpecDirectory

ACIQ ACIQ-42-HPDvsACIQ N5H5S42*K*AAA*

Side-by-side heat pump comparison

ACIQ ACIQ-42-HPD

SEER2

16.7BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

42000BTU/hr

Cold Climate

Yes

Cold climate certified

ACIQ N5H5S42*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

41500–42500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

ACIQ ACIQ-42-HPD is 7% more efficient at 16.7 BTU/Wh versus 15.5 BTU/Wh for the ACIQ N5H5S42*K*AAA*. The ACIQ N5H5S42*K*AAA* is larger at 42500 BTU/hr versus 42000 BTU/hr. Overall, the ACIQ ACIQ-42-HPD sits higher in the category, ranking above 79% of certified air-source heat pumps.

Efficiency

SpecACIQACIQ
SEER2 (best combination)(BTU/Wh)16.715.5
SEER2 (worst combination)(BTU/Wh)16.715.2
HSPF2 (best combination)(BTU/Wh)9.57.8
HSPF2 (worst combination)(BTU/Wh)9.57.8
EER2 (best combination)(BTU/Wh)11.713
COP at 5 °F1.902.26

Capacity

SpecACIQACIQ
Cooling Capacity (max)(BTU/hr)4200042500
Cooling Capacity (min)(BTU/hr)4200041500
Heating at 47 °F(BTU/hr)5000040500
Heating at 17 °F(BTU/hr)3700025600
Heating at 5 °F(BTU/hr)4600019900

Configuration

SpecACIQACIQ
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesACIQ SeriesPERFORMANCE 16 SEER2 HP
Indoor-Unit Combinations Rated13

Refrigerant

SpecACIQACIQ
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)