SpecDirectory

ACIQ ACIQ-42Z-E-HH-M5vsACIQ N5H5S42*K*AAA*

Side-by-side heat pump comparison

ACIQ ACIQ-42Z-E-HH-M5

SEER2

22–24BTU/Wh

HSPF2

10–10.5BTU/Wh

Cooling Capacity

42000BTU/hr

Cold Climate

Yes

Cold climate certified

ACIQ N5H5S42*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

41500–42500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

ACIQ ACIQ-42Z-E-HH-M5 is 35% more efficient at 24.0 BTU/Wh versus 15.5 BTU/Wh for the ACIQ N5H5S42*K*AAA*. The ACIQ N5H5S42*K*AAA* is larger at 42500 BTU/hr versus 42000 BTU/hr. ACIQ N5H5S42*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the ACIQ ACIQ-42Z-E-HH-M5 sits higher in the category, ranking above 84% of certified air-source heat pumps.

Efficiency

SpecACIQACIQ
SEER2 (best combination)(BTU/Wh)2415.5
SEER2 (worst combination)(BTU/Wh)2215.2
HSPF2 (best combination)(BTU/Wh)10.57.8
HSPF2 (worst combination)(BTU/Wh)107.8
EER2 (best combination)(BTU/Wh)12.513
COP at 5 °F2.102.26

Capacity

SpecACIQACIQ
Cooling Capacity (max)(BTU/hr)4200042500
Cooling Capacity (min)(BTU/hr)4200041500
Heating at 47 °F(BTU/hr)4200040500
Heating at 17 °F(BTU/hr)3640025600
Heating at 5 °F(BTU/hr)3500019900

Configuration

SpecACIQACIQ
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesMulti-spilt seriesPERFORMANCE 16 SEER2 HP
Indoor-Unit Combinations Rated33

Refrigerant

SpecACIQACIQ
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons