SpecDirectory

ACIQ B5H0V36*K*AAA*vsAmerican Standard 5WCZ5036A1

Side-by-side heat pump comparison

ACIQ B5H0V36*K*AAA*

SEER2

16–19.5BTU/Wh

HSPF2

8.5–9.5BTU/Wh

Cooling Capacity

32600–35400BTU/hr

Cold Climate

Yes

Cold climate certified

American Standard 5WCZ5036A1

SEER2

15.2BTU/Wh

HSPF2

7.7BTU/Wh

Cooling Capacity

35200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

ACIQ B5H0V36*K*AAA* is 22% more efficient at 19.5 BTU/Wh versus 15.2 BTU/Wh for the American Standard 5WCZ5036A1. The ACIQ B5H0V36*K*AAA* is larger at 35400 BTU/hr versus 35200 BTU/hr. Overall, the ACIQ B5H0V36*K*AAA* sits higher in the category, ranking above 69% of certified air-source heat pumps.

Efficiency

SpecACIQAmerican Standard
SEER2 (best combination)(BTU/Wh)19.515.2
SEER2 (worst combination)(BTU/Wh)1615.2
HSPF2 (best combination)(BTU/Wh)9.57.7
HSPF2 (worst combination)(BTU/Wh)8.57.7
EER2 (best combination)(BTU/Wh)11.511.5
COP at 5 °F2.042

Capacity

SpecACIQAmerican Standard
Cooling Capacity (max)(BTU/hr)3540035200
Cooling Capacity (min)(BTU/hr)3260035200
Heating at 47 °F(BTU/hr)3620033000
Heating at 17 °F(BTU/hr)3140021800
Heating at 5 °F(BTU/hr)2600017600

Configuration

SpecACIQAmerican Standard
Product TypeHP - Split SystemHP - Single Package
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesDeluxe 20 VS Heat Pump5WCZ5
Indoor-Unit Combinations Rated2701

Refrigerant

SpecACIQAmerican Standard
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)