SpecDirectory

ACIQ B5H0V36*K*AAA*vsJohnson Controls HMH72B341

Side-by-side heat pump comparison

ACIQ B5H0V36*K*AAA*

SEER2

16–19.5BTU/Wh

HSPF2

8.5–9.5BTU/Wh

Cooling Capacity

32600–35400BTU/hr

Cold Climate

Yes

Cold climate certified

Johnson Controls HMH72B341

SEER2

15.5–18.5BTU/Wh

HSPF2

8.1–8.5BTU/Wh

Cooling Capacity

31400–35200BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

ACIQ B5H0V36*K*AAA* is 5% more efficient at 19.5 BTU/Wh versus 18.5 BTU/Wh for the Johnson Controls HMH72B341. The ACIQ B5H0V36*K*AAA* is larger at 35400 BTU/hr versus 35200 BTU/hr. ACIQ B5H0V36*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecACIQJohnson Controls
SEER2 (best combination)(BTU/Wh)19.518.5
SEER2 (worst combination)(BTU/Wh)1615.5
HSPF2 (best combination)(BTU/Wh)9.58.5
HSPF2 (worst combination)(BTU/Wh)8.58.1
EER2 (best combination)(BTU/Wh)11.510.5
COP at 5 °F2.042.18

Capacity

SpecACIQJohnson Controls
Cooling Capacity (max)(BTU/hr)3540035200
Cooling Capacity (min)(BTU/hr)3260031400
Heating at 47 °F(BTU/hr)3620035200
Heating at 17 °F(BTU/hr)3140027000
Heating at 5 °F(BTU/hr)2600025000

Configuration

SpecACIQJohnson Controls
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesDeluxe 20 VS Heat PumpHMH7
Indoor-Unit Combinations Rated270844

Refrigerant

SpecACIQJohnson Controls
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)