SpecDirectory

ACIQ N5H5S24*K*AAA*vsJohnson Controls HL19B2421

Side-by-side heat pump comparison

ACIQ N5H5S24*K*AAA*

SEER2

15.2–16.5BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

22200–24400BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Johnson Controls HL19B2421

SEER2

16–18BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

21200–24200BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Johnson Controls HL19B2421 is 8% more efficient at 18.0 BTU/Wh versus 16.5 BTU/Wh for the ACIQ N5H5S24*K*AAA*. The ACIQ N5H5S24*K*AAA* is larger at 24400 BTU/hr versus 24200 BTU/hr. ACIQ N5H5S24*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecACIQJohnson Controls
SEER2 (best combination)(BTU/Wh)16.518
SEER2 (worst combination)(BTU/Wh)15.216
HSPF2 (best combination)(BTU/Wh)8.57.8
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1314
COP at 5 °F2.262.06

Capacity

SpecACIQJohnson Controls
Cooling Capacity (max)(BTU/hr)2440024200
Cooling Capacity (min)(BTU/hr)2220021200
Heating at 47 °F(BTU/hr)2400023800
Heating at 17 °F(BTU/hr)1520015200
Heating at 5 °F(BTU/hr)1190012200

Configuration

SpecACIQJohnson Controls
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesPERFORMANCE 16 SEER2 HPMOMENTUM
Indoor-Unit Combinations Rated18285

Refrigerant

SpecACIQJohnson Controls
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)