SpecDirectory

ACIQ N5H8T36*K*AAA*vsXTRON XM5-H42/2DR3A

Side-by-side heat pump comparison

ACIQ N5H8T36*K*AAA*

SEER2

15.2–17BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

33800–37600BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

XTRON XM5-H42/2DR3A

SEER2

20–22BTU/Wh

HSPF2

9.2–10BTU/Wh

Cooling Capacity

37000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

XTRON XM5-H42/2DR3A is 23% more efficient at 22.0 BTU/Wh versus 17.0 BTU/Wh for the ACIQ N5H8T36*K*AAA*. The ACIQ N5H8T36*K*AAA* is larger at 37600 BTU/hr versus 37000 BTU/hr. ACIQ N5H8T36*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecACIQXTRON
SEER2 (best combination)(BTU/Wh)1722
SEER2 (worst combination)(BTU/Wh)15.220
HSPF2 (best combination)(BTU/Wh)8.510
HSPF2 (worst combination)(BTU/Wh)7.89.2
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F2.482

Capacity

SpecACIQXTRON
Cooling Capacity (max)(BTU/hr)3760037000
Cooling Capacity (min)(BTU/hr)3380037000
Heating at 47 °F(BTU/hr)3900037000
Heating at 17 °F(BTU/hr)2420035600
Heating at 5 °F(BTU/hr)1960032400

Configuration

SpecACIQXTRON
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series2-STAGE 18 SEER HPmulti-Series
Indoor-Unit Combinations Rated2493

Refrigerant

SpecACIQXTRON
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)

More comparisons