SpecDirectory

ACIQ PHR536000K***K1vsAmeristar A5HL5036A1

Side-by-side heat pump comparison

ACIQ PHR536000K***K1

SEER2

15.5BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

34200BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Ameristar A5HL5036A1

SEER2

15.2–16BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

33000–34000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Ameristar A5HL5036A1 is 3% more efficient at 16.0 BTU/Wh versus 15.5 BTU/Wh for the ACIQ PHR536000K***K1. The ACIQ PHR536000K***K1 is larger at 34200 BTU/hr versus 34000 BTU/hr. Ameristar A5HL5036A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecACIQAmeristar
SEER2 (best combination)(BTU/Wh)15.516
SEER2 (worst combination)(BTU/Wh)15.515.2
HSPF2 (best combination)(BTU/Wh)7.28.1
HSPF2 (worst combination)(BTU/Wh)7.28.1
EER2 (best combination)(BTU/Wh)1211.7
COP at 5 °F1.771.80

Capacity

SpecACIQAmeristar
Cooling Capacity (max)(BTU/hr)3420034000
Cooling Capacity (min)(BTU/hr)3420033000
Heating at 47 °F(BTU/hr)3440035000
Heating at 17 °F(BTU/hr)1890032000
Heating at 5 °F(BTU/hr)1270030000

Configuration

SpecACIQAmeristar
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageTwo-stage
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesQuiet Comfort HPA5HL5
Indoor-Unit Combinations Rated130

Refrigerant

SpecACIQAmeristar
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)