SpecDirectory

ACIQ PHR536000K***K1vsJetson HP-36ODU-001

Side-by-side heat pump comparison

ACIQ PHR536000K***K1

SEER2

15.5BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

34200BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Jetson HP-36ODU-001

SEER2

17BTU/Wh

HSPF2

9.4BTU/Wh

Cooling Capacity

34000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Jetson HP-36ODU-001 is 9% more efficient at 17.0 BTU/Wh versus 15.5 BTU/Wh for the ACIQ PHR536000K***K1. The ACIQ PHR536000K***K1 is larger at 34200 BTU/hr versus 34000 BTU/hr. Jetson HP-36ODU-001 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Jetson HP-36ODU-001 sits higher in the category, ranking above 65% of certified air-source heat pumps.

Efficiency

SpecACIQJetson
SEER2 (best combination)(BTU/Wh)15.517
SEER2 (worst combination)(BTU/Wh)15.517
HSPF2 (best combination)(BTU/Wh)7.29.4
HSPF2 (worst combination)(BTU/Wh)7.29.4
EER2 (best combination)(BTU/Wh)1211.7
COP at 5 °F1.771.90

Capacity

SpecACIQJetson
Cooling Capacity (max)(BTU/hr)3420034000
Cooling Capacity (min)(BTU/hr)3420034000
Heating at 47 °F(BTU/hr)3440036000
Heating at 17 °F(BTU/hr)1890031200
Heating at 5 °F(BTU/hr)1270036000

Configuration

SpecACIQJetson
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesQuiet Comfort HPHP Series
Indoor-Unit Combinations Rated12

Refrigerant

SpecACIQJetson
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)