SpecDirectory

ACIQ PHR560000K***K1vsAirquest D5CUHAH60AAK+KSAIC0701230

Side-by-side heat pump comparison

ACIQ PHR560000K***K1

SEER2

15.2BTU/Wh

HSPF2

7.5BTU/Wh

Cooling Capacity

56000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Airquest D5CUHAH60AAK+KSAIC0701230

SEER2

15.2–16BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

55500–56500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Airquest D5CUHAH60AAK+KSAIC0701230 is 5% more efficient at 16.0 BTU/Wh versus 15.2 BTU/Wh for the ACIQ PHR560000K***K1. The Airquest D5CUHAH60AAK+KSAIC0701230 is larger at 56500 BTU/hr versus 56000 BTU/hr. Airquest D5CUHAH60AAK+KSAIC0701230 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Airquest D5CUHAH60AAK+KSAIC0701230 sits higher in the category, ranking above 14% of certified air-source heat pumps.

Efficiency

SpecACIQAirquest
SEER2 (best combination)(BTU/Wh)15.216
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)7.59
HSPF2 (worst combination)(BTU/Wh)7.59
EER2 (best combination)(BTU/Wh)11.59.8
COP at 5 °F21.78

Capacity

SpecACIQAirquest
Cooling Capacity (max)(BTU/hr)5600056500
Cooling Capacity (min)(BTU/hr)5600055500
Heating at 47 °F(BTU/hr)5650056500
Heating at 17 °F(BTU/hr)3240041000
Heating at 5 °F(BTU/hr)2220051500

Configuration

SpecACIQAirquest
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesQuiet Comfort HPCrossover Heat Pump
Indoor-Unit Combinations Rated12

Refrigerant

SpecACIQAirquest
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)