SpecDirectory

ACIQ R5H5S42*K*AAA*vsFujitsu AOUH45KWAS5

Side-by-side heat pump comparison

ACIQ R5H5S42*K*AAA*

SEER2

15.2–15.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

41500–42500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Fujitsu AOUH45KWAS5

SEER2

19–22BTU/Wh

HSPF2

9–10BTU/Wh

Cooling Capacity

43000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Fujitsu AOUH45KWAS5 is 30% more efficient at 22.0 BTU/Wh versus 15.5 BTU/Wh for the ACIQ R5H5S42*K*AAA*. The Fujitsu AOUH45KWAS5 is larger at 43000 BTU/hr versus 42500 BTU/hr. ACIQ R5H5S42*K*AAA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the Fujitsu AOUH45KWAS5 sits higher in the category, ranking above 80% of certified air-source heat pumps.

Efficiency

SpecACIQFujitsu
SEER2 (best combination)(BTU/Wh)15.522
SEER2 (worst combination)(BTU/Wh)15.219
HSPF2 (best combination)(BTU/Wh)7.810
HSPF2 (worst combination)(BTU/Wh)7.89
EER2 (best combination)(BTU/Wh)1312
COP at 5 °F2.262.14

Capacity

SpecACIQFujitsu
Cooling Capacity (max)(BTU/hr)4250043000
Cooling Capacity (min)(BTU/hr)4150043000
Heating at 47 °F(BTU/hr)4050048000
Heating at 17 °F(BTU/hr)2560031000
Heating at 5 °F(BTU/hr)1990036000

Configuration

SpecACIQFujitsu
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series15 SEER2 HPAIRSTAGE H-series
Indoor-Unit Combinations Rated33

Refrigerant

SpecACIQFujitsu
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)

More comparisons