SpecDirectory

AireForce DXH09PSK3IHvsCanAir 4C25SCH09H21

Side-by-side heat pump comparison

AireForce DXH09PSK3IH

SEER2

24–26BTU/Wh

HSPF2

9.2–10.4BTU/Wh

Cooling Capacity

9100BTU/hr

Cold Climate

Yes

Cold climate certified

CanAir 4C25SCH09H21

SEER2

19.5–25.8BTU/Wh

HSPF2

11–13BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 26.0 vs 25.8 BTU/Wh. The AireForce DXH09PSK3IH is larger at 9100 BTU/hr versus 9000 BTU/hr. CanAir 4C25SCH09H21 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecAireForceCanAir
SEER2 (best combination)(BTU/Wh)2625.8
SEER2 (worst combination)(BTU/Wh)2419.5
HSPF2 (best combination)(BTU/Wh)10.413
HSPF2 (worst combination)(BTU/Wh)9.211
EER2 (best combination)(BTU/Wh)1514.9
COP at 5 °F1.942.36

Capacity

SpecAireForceCanAir
Cooling Capacity (max)(BTU/hr)91009000
Cooling Capacity (min)(BTU/hr)91009000
Heating at 47 °F(BTU/hr)1050011000
Heating at 17 °F(BTU/hr)110009300
Heating at 5 °F(BTU/hr)95008600

Configuration

SpecAireForceCanAir
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesMultizone Indoors Eight-way Compact Cassettes4C Series
Indoor-Unit Combinations Rated28

Refrigerant

SpecAireForceCanAir
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons