SpecDirectory

AireForce DXH09PSK3IHvsGoodman MSH093E23MCAA

Side-by-side heat pump comparison

AireForce DXH09PSK3IH

SEER2

24–26BTU/Wh

HSPF2

9.2–10.4BTU/Wh

Cooling Capacity

9100BTU/hr

Cold Climate

Yes

Cold climate certified

Goodman MSH093E23MCAA

SEER2

20.2–25BTU/Wh

HSPF2

10.3–12BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AireForce DXH09PSK3IH is 4% more efficient at 26.0 BTU/Wh versus 25.0 BTU/Wh for the Goodman MSH093E23MCAA. The AireForce DXH09PSK3IH is larger at 9100 BTU/hr versus 9000 BTU/hr. AireForce DXH09PSK3IH uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecAireForceGoodman
SEER2 (best combination)(BTU/Wh)2625
SEER2 (worst combination)(BTU/Wh)2420.2
HSPF2 (best combination)(BTU/Wh)10.412
HSPF2 (worst combination)(BTU/Wh)9.210.3
EER2 (best combination)(BTU/Wh)1515.6
COP at 5 °F1.941.90

Capacity

SpecAireForceGoodman
Cooling Capacity (max)(BTU/hr)91009000
Cooling Capacity (min)(BTU/hr)91009000
Heating at 47 °F(BTU/hr)1050011500
Heating at 17 °F(BTU/hr)1100010100
Heating at 5 °F(BTU/hr)950010800

Configuration

SpecAireForceGoodman
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesMultizone Indoors Eight-way Compact CassettesMSH Series
Indoor-Unit Combinations Rated23

Refrigerant

SpecAireForceGoodman
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)