SpecDirectory

Airquest D5CMRAH18CAKvsAirquest N4H5S18*K*AAA*

Side-by-side heat pump comparison

Airquest D5CMRAH18CAK

SEER2

20–25.2BTU/Wh

HSPF2

9.8–10BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Airquest N4H5S18*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

18000–18100BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Airquest D5CMRAH18CAK is 40% more efficient at 25.2 BTU/Wh versus 15.2 BTU/Wh for the Airquest N4H5S18*K*AAA*. The Airquest N4H5S18*K*AAA* is larger at 18100 BTU/hr versus 18000 BTU/hr. Airquest D5CMRAH18CAK uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Airquest D5CMRAH18CAK sits higher in the category, ranking above 92% of certified air-source heat pumps.

Efficiency

SpecAirquestAirquest
SEER2 (best combination)(BTU/Wh)25.215.2
SEER2 (worst combination)(BTU/Wh)2015.2
HSPF2 (best combination)(BTU/Wh)107.8
HSPF2 (worst combination)(BTU/Wh)9.87.8
EER2 (best combination)(BTU/Wh)1412
COP at 5 °F2.30—

Capacity

SpecAirquestAirquest
Cooling Capacity (max)(BTU/hr)1800018100
Cooling Capacity (min)(BTU/hr)1800018000
Heating at 47 °F(BTU/hr)1900016700
Heating at 17 °F(BTU/hr)1600010400
Heating at 5 °F(BTU/hr)14600—

Configuration

SpecAirquestAirquest
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesD5C SeriesPERFORMANCE 15 SEER2 HP
Indoor-Unit Combinations Rated32

Refrigerant

SpecAirquestAirquest
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons