SpecDirectory

Airquest D5CUHAH30AAKvsCHAMPION HEATING AND COOLING XH630E2S11

Side-by-side heat pump comparison

Airquest D5CUHAH30AAK

SEER2

15.2–17.5BTU/Wh

HSPF2

9–10.8BTU/Wh

Cooling Capacity

29000–31200BTU/hr

Cold Climate

Yes

Cold climate certified

CHAMPION HEATING AND COOLING XH630E2S11

SEER2

15.2–17BTU/Wh

HSPF2

8–8.1BTU/Wh

Cooling Capacity

28400–31000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Airquest D5CUHAH30AAK is 3% more efficient at 17.5 BTU/Wh versus 17.0 BTU/Wh for the CHAMPION HEATING AND COOLING XH630E2S11. The Airquest D5CUHAH30AAK is larger at 31200 BTU/hr versus 31000 BTU/hr.

Efficiency

SpecAirquestCHAMPION HEATING AND COOLING
SEER2 (best combination)(BTU/Wh)17.517
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)10.88.1
HSPF2 (worst combination)(BTU/Wh)98
EER2 (best combination)(BTU/Wh)12.113
COP at 5 °F22.40

Capacity

SpecAirquestCHAMPION HEATING AND COOLING
Cooling Capacity (max)(BTU/hr)3120031000
Cooling Capacity (min)(BTU/hr)2900028400
Heating at 47 °F(BTU/hr)3420030000
Heating at 17 °F(BTU/hr)2500020200
Heating at 5 °F(BTU/hr)3320016400

Configuration

SpecAirquestCHAMPION HEATING AND COOLING
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesD5F SeriesLX SERIES
Indoor-Unit Combinations Rated11207

Refrigerant

SpecAirquestCHAMPION HEATING AND COOLING
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons