Airquest D5CUHAH60AAK+KSAIC0701230vsKenmore PHR560000K***K1
Side-by-side heat pump comparison
Airquest D5CUHAH60AAK+KSAIC0701230
SEER2
15.2–16BTU/Wh
HSPF2
9BTU/Wh
Cooling Capacity
55500–56500BTU/hr
Cold Climate
Yes
Cold climate certified
Kenmore PHR560000K***K1
SEER2
15.2BTU/Wh
HSPF2
7.5BTU/Wh
Cooling Capacity
56000BTU/hr
Refrigerant
R-410A
GWP 2088 · Higher
Key differences
Airquest D5CUHAH60AAK+KSAIC0701230 is 5% more efficient at 16.0 BTU/Wh versus 15.2 BTU/Wh for the Kenmore PHR560000K***K1. The Airquest D5CUHAH60AAK+KSAIC0701230 is larger at 56500 BTU/hr versus 56000 BTU/hr. Airquest D5CUHAH60AAK+KSAIC0701230 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Airquest D5CUHAH60AAK+KSAIC0701230 sits higher in the category, ranking above 14% of certified air-source heat pumps.
Efficiency
| Spec | Airquest | Kenmore |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 16 | 15.2 |
| SEER2 (worst combination)(BTU/Wh) | 15.2 | 15.2 |
| HSPF2 (best combination)(BTU/Wh) | 9 | 7.5 |
| HSPF2 (worst combination)(BTU/Wh) | 9 | 7.5 |
| EER2 (best combination)(BTU/Wh) | 9.8 | 11.5 |
| COP at 5 °F | 1.78 | 2 |
Capacity
| Spec | Airquest | Kenmore |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 56500 | 56000 |
| Cooling Capacity (min)(BTU/hr) | 55500 | 56000 |
| Heating at 47 °F(BTU/hr) | 56500 | 56500 |
| Heating at 17 °F(BTU/hr) | 41000 | 32400 |
| Heating at 5 °F(BTU/hr) | 51500 | 22200 |
Configuration
| Spec | Airquest | Kenmore |
|---|---|---|
| Product Type | HP - Split System | HP - Single Package |
| Compressor Staging | Continuously variable | Two-stage |
| Cold Climate Certified | Yes | No |
| Connected Capability | No | No |
| Series | Crossover Heat Pump | Quiet Comfort HP |
| Indoor-Unit Combinations Rated | 2 | 1 |
Refrigerant
| Spec | Airquest | Kenmore |
|---|---|---|
| Type | R-454B | R-410A |
| GWP Rating | R-454B (GWP:470 | Lower GWP) | R-410A (GWP:2088) |