SpecDirectory

Airquest N4H5S18*K*AAA*vsArmstrong Air A7HP14F18P-**A

Side-by-side heat pump comparison

Airquest N4H5S18*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

18000–18100BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Armstrong Air A7HP14F18P-**A

SEER2

15.2–16.5BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

18000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Armstrong Air A7HP14F18P-**A is 8% more efficient at 16.5 BTU/Wh versus 15.2 BTU/Wh for the Airquest N4H5S18*K*AAA*. The Airquest N4H5S18*K*AAA* is larger at 18100 BTU/hr versus 18000 BTU/hr. Armstrong Air A7HP14F18P-**A uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Armstrong Air A7HP14F18P-**A sits higher in the category, ranking above 25% of certified air-source heat pumps.

Efficiency

SpecAirquestArmstrong Air
SEER2 (best combination)(BTU/Wh)15.216.5
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)7.87.8
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1214.2
COP at 5 °F—2.06

Capacity

SpecAirquestArmstrong Air
Cooling Capacity (max)(BTU/hr)1810018000
Cooling Capacity (min)(BTU/hr)1800018000
Heating at 47 °F(BTU/hr)1670018000
Heating at 17 °F(BTU/hr)1040011200
Heating at 5 °F(BTU/hr)—8500

Configuration

SpecAirquestArmstrong Air
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageSingle stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesPERFORMANCE 15 SEER2 HPA7HP14F Series
Indoor-Unit Combinations Rated251

Refrigerant

SpecAirquestArmstrong Air
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)