SpecDirectory

Airquest N4H5S18*K*AAA*vsComfort-Aire A-ZHP18SA-1

Side-by-side heat pump comparison

Airquest N4H5S18*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

18000–18100BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Comfort-Aire A-ZHP18SA-1

SEER2

25.6BTU/Wh

HSPF2

16.2BTU/Wh

Cooling Capacity

18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Comfort-Aire A-ZHP18SA-1 is 41% more efficient at 25.6 BTU/Wh versus 15.2 BTU/Wh for the Airquest N4H5S18*K*AAA*. The Airquest N4H5S18*K*AAA* is larger at 18100 BTU/hr versus 18000 BTU/hr. Comfort-Aire A-ZHP18SA-1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Comfort-Aire A-ZHP18SA-1 sits higher in the category, ranking above 94% of certified air-source heat pumps.

Efficiency

SpecAirquestComfort-Aire
SEER2 (best combination)(BTU/Wh)15.225.6
SEER2 (worst combination)(BTU/Wh)15.225.6
HSPF2 (best combination)(BTU/Wh)7.816.2
HSPF2 (worst combination)(BTU/Wh)7.816.2
EER2 (best combination)(BTU/Wh)1215
COP at 5 °F—2.34

Capacity

SpecAirquestComfort-Aire
Cooling Capacity (max)(BTU/hr)1810018000
Cooling Capacity (min)(BTU/hr)1800018000
Heating at 47 °F(BTU/hr)1670020000
Heating at 17 °F(BTU/hr)1040019300
Heating at 5 °F(BTU/hr)—22600

Configuration

SpecAirquestComfort-Aire
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesPERFORMANCE 15 SEER2 HPA-ZHP Series
Indoor-Unit Combinations Rated21

Refrigerant

SpecAirquestComfort-Aire
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons