SpecDirectory

Airquest N4H5S18*K*AAA*vsMitsubishi Electric SUZ-KA18NAHZ

Side-by-side heat pump comparison

Airquest N4H5S18*K*AAA*

SEER2

15.2BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

18000–18100BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Mitsubishi Electric SUZ-KA18NAHZ

SEER2

18.3–19.2BTU/Wh

HSPF2

8.5–9.2BTU/Wh

Cooling Capacity

16700–18000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Mitsubishi Electric SUZ-KA18NAHZ is 21% more efficient at 19.2 BTU/Wh versus 15.2 BTU/Wh for the Airquest N4H5S18*K*AAA*. The Airquest N4H5S18*K*AAA* is larger at 18100 BTU/hr versus 18000 BTU/hr. Overall, the Mitsubishi Electric SUZ-KA18NAHZ sits higher in the category, ranking above 25% of certified air-source heat pumps.

Efficiency

SpecAirquestMitsubishi Electric
SEER2 (best combination)(BTU/Wh)15.219.2
SEER2 (worst combination)(BTU/Wh)15.218.3
HSPF2 (best combination)(BTU/Wh)7.89.2
HSPF2 (worst combination)(BTU/Wh)7.88.5
EER2 (best combination)(BTU/Wh)1212.5
COP at 5 °F—2.06

Capacity

SpecAirquestMitsubishi Electric
Cooling Capacity (max)(BTU/hr)1810018000
Cooling Capacity (min)(BTU/hr)1800016700
Heating at 47 °F(BTU/hr)1670021600
Heating at 17 °F(BTU/hr)1040014300
Heating at 5 °F(BTU/hr)—21600

Configuration

SpecAirquestMitsubishi Electric
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesPERFORMANCE 15 SEER2 HPM-Series
Indoor-Unit Combinations Rated24

Refrigerant

SpecAirquestMitsubishi Electric
TypeR-410AR-410A
GWP RatingR-410A (GWP:2088)R-410A (GWP:2088)

More comparisons