Airquest PHB536000K000B*vsCanAir MOE31U-36HFN1-M

Side-by-side heat pump comparison

Airquest PHB536000K000B*

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

35200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

CanAir MOE31U-36HFN1-M

SEER2

15.2BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

35000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

The Airquest PHB536000K000B* is larger at 35200 BTU/hr versus 35000 BTU/hr. Airquest PHB536000K000B* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecAirquestCanAir
SEER2 (best combination)(BTU/Wh)15.215.2
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)7.210
HSPF2 (worst combination)(BTU/Wh)7.210
EER2 (best combination)(BTU/Wh)11.510
COP at 5 °F1.702

Capacity

SpecAirquestCanAir
Cooling Capacity (max)(BTU/hr)3520035000
Cooling Capacity (min)(BTU/hr)3520035000
Heating at 47 °F(BTU/hr)3440039000
Heating at 17 °F(BTU/hr)1960033000
Heating at 5 °F(BTU/hr)1410032000

Configuration

SpecAirquestCanAir
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesQuiet Comfort HPMAC series
Indoor-Unit Combinations Rated11

Refrigerant

SpecAirquestCanAir
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)