SpecDirectory

Airquest PHB536000K000B*vsColeman XH536E2S11

Side-by-side heat pump comparison

Airquest PHB536000K000B*

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

35200BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Coleman XH536E2S11

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

32400–35000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Coleman XH536E2S11 is 5% more efficient at 16.0 BTU/Wh versus 15.2 BTU/Wh for the Airquest PHB536000K000B*. The Airquest PHB536000K000B* is larger at 35200 BTU/hr versus 35000 BTU/hr. Overall, the Coleman XH536E2S11 sits higher in the category, ranking above 14% of certified air-source heat pumps.

Efficiency

SpecAirquestColeman
SEER2 (best combination)(BTU/Wh)15.216
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)7.28.1
HSPF2 (worst combination)(BTU/Wh)7.27.8
EER2 (best combination)(BTU/Wh)11.512
COP at 5 °F1.702.44

Capacity

SpecAirquestColeman
Cooling Capacity (max)(BTU/hr)3520035000
Cooling Capacity (min)(BTU/hr)3520032400
Heating at 47 °F(BTU/hr)3440032800
Heating at 17 °F(BTU/hr)1960022000
Heating at 5 °F(BTU/hr)1410018400

Configuration

SpecAirquestColeman
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesQuiet Comfort HPLX SERIES
Indoor-Unit Combinations Rated1275

Refrigerant

SpecAirquestColeman
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons