Airtemp DXH24PSK3IH

SEER2

26BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

22000BTU/hr

Cold Climate

Yes

Cold climate certified

Daikin RXP24AVJU*

SEER2

18.3BTU/Wh

HSPF2

9.2BTU/Wh

Cooling Capacity

21800BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Airtemp DXH24PSK3IH is 30% more efficient at 26.0 BTU/Wh versus 18.3 BTU/Wh for the Daikin RXP24AVJU*. The Airtemp DXH24PSK3IH is larger at 22000 BTU/hr versus 21800 BTU/hr. Overall, the Airtemp DXH24PSK3IH sits higher in the category, ranking above 94% of certified air-source heat pumps.

Efficiency

SpecAirtempDaikin
SEER2 (best combination)(BTU/Wh)2618.3
SEER2 (worst combination)(BTU/Wh)2618.3
HSPF2 (best combination)(BTU/Wh)109.2
HSPF2 (worst combination)(BTU/Wh)109.2
EER2 (best combination)(BTU/Wh)13.710.3
COP at 5 °F1.801.80

Capacity

SpecAirtempDaikin
Cooling Capacity (max)(BTU/hr)2200021800
Cooling Capacity (min)(BTU/hr)2200021800
Heating at 47 °F(BTU/hr)2400024000
Heating at 17 °F(BTU/hr)2000016600
Heating at 5 °F(BTU/hr)1900024000

Configuration

SpecAirtempDaikin
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
Series(24-26 SEER2) MinisplitsAURORA
Indoor-Unit Combinations Rated11

Refrigerant

SpecAirtempDaikin
TypeR-32R-32
GWP RatingR-32 (GWP:675 | Lower GWP)R-32 (GWP:675 | Lower GWP)