SpecDirectory

American Standard 5A6V0X36A1vsLG LUU360HHV

Side-by-side heat pump comparison

American Standard 5A6V0X36A1

SEER2

19.2–21BTU/Wh

HSPF2

9.4–10.5BTU/Wh

Cooling Capacity

34600–36200BTU/hr

Cold Climate

Yes

Cold climate certified

LG LUU360HHV

SEER2

16.4–21.5BTU/Wh

HSPF2

9.2–10.6BTU/Wh

Cooling Capacity

33000–36000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 21.0 vs 21.5 BTU/Wh. The American Standard 5A6V0X36A1 is larger at 36200 BTU/hr versus 36000 BTU/hr. American Standard 5A6V0X36A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecAmerican StandardLG
SEER2 (best combination)(BTU/Wh)2121.5
SEER2 (worst combination)(BTU/Wh)19.216.4
HSPF2 (best combination)(BTU/Wh)10.510.6
HSPF2 (worst combination)(BTU/Wh)9.49.2
EER2 (best combination)(BTU/Wh)1312.6
COP at 5 °F2.242.10

Capacity

SpecAmerican StandardLG
Cooling Capacity (max)(BTU/hr)3620036000
Cooling Capacity (min)(BTU/hr)3460033000
Heating at 47 °F(BTU/hr)3320040000
Heating at 17 °F(BTU/hr)3160025400
Heating at 5 °F(BTU/hr)2540037000

Configuration

SpecAmerican StandardLG
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesPLATINUM 20LUU360HHV
Indoor-Unit Combinations Rated1133

Refrigerant

SpecAmerican StandardLG
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons