American Standard 5A6V0X36A1

SEER2

19.2–21BTU/Wh

HSPF2

9.4–10.5BTU/Wh

Cooling Capacity

34600–36200BTU/hr

Cold Climate

Yes

Cold climate certified

Maytag PSH4BF5M2SX36K

SEER2

16BTU/Wh

HSPF2

8BTU/Wh

Cooling Capacity

36000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

American Standard 5A6V0X36A1 is 24% more efficient at 21.0 BTU/Wh versus 16.0 BTU/Wh for the Maytag PSH4BF5M2SX36K. The American Standard 5A6V0X36A1 is larger at 36200 BTU/hr versus 36000 BTU/hr. Overall, the American Standard 5A6V0X36A1 sits higher in the category, ranking above 77% of certified air-source heat pumps.

Efficiency

SpecAmerican StandardMaytag
SEER2 (best combination)(BTU/Wh)2116
SEER2 (worst combination)(BTU/Wh)19.216
HSPF2 (best combination)(BTU/Wh)10.58
HSPF2 (worst combination)(BTU/Wh)9.48
EER2 (best combination)(BTU/Wh)1311.7
COP at 5 °F2.241.75

Capacity

SpecAmerican StandardMaytag
Cooling Capacity (max)(BTU/hr)3620036000
Cooling Capacity (min)(BTU/hr)3460036000
Heating at 47 °F(BTU/hr)3320034200
Heating at 17 °F(BTU/hr)3160021600
Heating at 5 °F(BTU/hr)2540017800

Configuration

SpecAmerican StandardMaytag
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesPLATINUM 20MAYTAG PSH4BF SERIES
Indoor-Unit Combinations Rated1131

Refrigerant

SpecAmerican StandardMaytag
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)