SpecDirectory

American Standard 5A6V0X36A1vsYork YVAHP036B21S*

Side-by-side heat pump comparison

American Standard 5A6V0X36A1

SEER2

19.2–21BTU/Wh

HSPF2

9.4–10.5BTU/Wh

Cooling Capacity

34600–36200BTU/hr

Cold Climate

Yes

Cold climate certified

York YVAHP036B21S*

SEER2

18.5–22.2BTU/Wh

HSPF2

9.5–10.8BTU/Wh

Cooling Capacity

36000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

York YVAHP036B21S* is 5% more efficient at 22.2 BTU/Wh versus 21.0 BTU/Wh for the American Standard 5A6V0X36A1. The American Standard 5A6V0X36A1 is larger at 36200 BTU/hr versus 36000 BTU/hr. American Standard 5A6V0X36A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecAmerican StandardYork
SEER2 (best combination)(BTU/Wh)2122.2
SEER2 (worst combination)(BTU/Wh)19.218.5
HSPF2 (best combination)(BTU/Wh)10.510.8
HSPF2 (worst combination)(BTU/Wh)9.49.5
EER2 (best combination)(BTU/Wh)1316.7
COP at 5 °F2.241.81

Capacity

SpecAmerican StandardYork
Cooling Capacity (max)(BTU/hr)3620036000
Cooling Capacity (min)(BTU/hr)3460036000
Heating at 47 °F(BTU/hr)3320036000
Heating at 17 °F(BTU/hr)3160023800
Heating at 5 °F(BTU/hr)2540031600

Configuration

SpecAmerican StandardYork
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesPLATINUM 20HMSV-A-CB
Indoor-Unit Combinations Rated1133

Refrigerant

SpecAmerican StandardYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons