SpecDirectory

American Standard 5A6V8X48A1vsYork PHG6B481002X4

Side-by-side heat pump comparison

American Standard 5A6V8X48A1

SEER2

18.1BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

43500–47000BTU/hr

Cold Climate

Yes

Cold climate certified

York PHG6B481002X4

SEER2

15.2BTU/Wh

HSPF2

7.2BTU/Wh

Cooling Capacity

46500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

American Standard 5A6V8X48A1 is 16% more efficient at 18.1 BTU/Wh versus 15.2 BTU/Wh for the York PHG6B481002X4. The American Standard 5A6V8X48A1 is larger at 47000 BTU/hr versus 46500 BTU/hr. American Standard 5A6V8X48A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the American Standard 5A6V8X48A1 sits higher in the category, ranking above 83% of certified air-source heat pumps.

Efficiency

SpecAmerican StandardYork
SEER2 (best combination)(BTU/Wh)18.115.2
SEER2 (worst combination)(BTU/Wh)18.115.2
HSPF2 (best combination)(BTU/Wh)8.57.2
HSPF2 (worst combination)(BTU/Wh)8.57.2
EER2 (best combination)(BTU/Wh)11.212
COP at 5 °F2.202.20

Capacity

SpecAmerican StandardYork
Cooling Capacity (max)(BTU/hr)4700046500
Cooling Capacity (min)(BTU/hr)4350046500
Heating at 47 °F(BTU/hr)4700045500
Heating at 17 °F(BTU/hr)4300030200
Heating at 5 °F(BTU/hr)3560024000

Configuration

SpecAmerican StandardYork
Product TypeHP - Split SystemHP - Single Package
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesPLATINUM 18LX SERIES
Indoor-Unit Combinations Rated1431

Refrigerant

SpecAmerican StandardYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons