American Standard 5HCL5060A1

SEER2

17BTU/Wh

HSPF2

9.3–9.4BTU/Wh

Cooling Capacity

48000–52000BTU/hr

Cold Climate

Yes

Cold climate certified

LG KUSUB601A

SEER2

18.5BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

52500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

LG KUSUB601A is 8% more efficient at 18.5 BTU/Wh versus 17.0 BTU/Wh for the American Standard 5HCL5060A1. The LG KUSUB601A is larger at 52500 BTU/hr versus 52000 BTU/hr. American Standard 5HCL5060A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecAmerican StandardLG
SEER2 (best combination)(BTU/Wh)1718.5
SEER2 (worst combination)(BTU/Wh)1718.5
HSPF2 (best combination)(BTU/Wh)9.49
HSPF2 (worst combination)(BTU/Wh)9.39
EER2 (best combination)(BTU/Wh)10.811
COP at 5 °F1.951.85

Capacity

SpecAmerican StandardLG
Cooling Capacity (max)(BTU/hr)5200052500
Cooling Capacity (min)(BTU/hr)4800052500
Heating at 47 °F(BTU/hr)5400055000
Heating at 17 °F(BTU/hr)4000034800
Heating at 5 °F(BTU/hr)4500038500

Configuration

SpecAmerican StandardLG
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
Series5HCL5 Cold ClimateKUSUB601A
Indoor-Unit Combinations Rated21

Refrigerant

SpecAmerican StandardLG
TypeR-454BR-32
GWP RatingR-454B (GWP:470 | Lower GWP)R-32 (GWP:675 | Lower GWP)