SpecDirectory

Armstrong Air A7SCP18V60P-**AvsYork YZT60B21

Side-by-side heat pump comparison

Armstrong Air A7SCP18V60P-**A

SEER2

15.2–18.3BTU/Wh

HSPF2

8.1–9.6BTU/Wh

Cooling Capacity

42500–55500BTU/hr

Cold Climate

Yes

Cold climate certified

York YZT60B21

SEER2

15.2–16BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

54000–55000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Armstrong Air A7SCP18V60P-**A is 13% more efficient at 18.3 BTU/Wh versus 16.0 BTU/Wh for the York YZT60B21. The Armstrong Air A7SCP18V60P-**A is larger at 55500 BTU/hr versus 55000 BTU/hr. Armstrong Air A7SCP18V60P-**A uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Armstrong Air A7SCP18V60P-**A sits higher in the category, ranking above 96% of certified air-source heat pumps.

Efficiency

SpecArmstrong AirYork
SEER2 (best combination)(BTU/Wh)18.316
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)9.67.8
HSPF2 (worst combination)(BTU/Wh)8.17.8
EER2 (best combination)(BTU/Wh)11.711.7
COP at 5 °F1.952.28

Capacity

SpecArmstrong AirYork
Cooling Capacity (max)(BTU/hr)5550055000
Cooling Capacity (min)(BTU/hr)4250054000
Heating at 47 °F(BTU/hr)5650060000
Heating at 17 °F(BTU/hr)4500040500
Heating at 5 °F(BTU/hr)4500033400

Configuration

SpecArmstrong AirYork
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesA7SCP18V SeriesAFFINITY
Indoor-Unit Combinations Rated25018

Refrigerant

SpecArmstrong AirYork
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons