AUFIT ASW-H24F6A2/**R3DI-D7vsTrane 5TWV8X24A1

Side-by-side heat pump comparison

AUFIT ASW-H24F6A2/**R3DI-D7

SEER2

25BTU/Wh

HSPF2

10.5BTU/Wh

Cooling Capacity

22400BTU/hr

Cold Climate

Yes

Cold climate certified

Trane 5TWV8X24A1

SEER2

18.1BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

21400–22200BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AUFIT ASW-H24F6A2/**R3DI-D7 is 28% more efficient at 25.0 BTU/Wh versus 18.1 BTU/Wh for the Trane 5TWV8X24A1. The AUFIT ASW-H24F6A2/**R3DI-D7 is larger at 22400 BTU/hr versus 22200 BTU/hr. Trane 5TWV8X24A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the AUFIT ASW-H24F6A2/**R3DI-D7 sits higher in the category, ranking above 89% of certified air-source heat pumps.

Efficiency

SpecAUFITTrane
SEER2 (best combination)(BTU/Wh)2518.1
SEER2 (worst combination)(BTU/Wh)2518.1
HSPF2 (best combination)(BTU/Wh)10.58.5
HSPF2 (worst combination)(BTU/Wh)10.58.5
EER2 (best combination)(BTU/Wh)1411.5
COP at 5 °F2.102.27

Capacity

SpecAUFITTrane
Cooling Capacity (max)(BTU/hr)2240022200
Cooling Capacity (min)(BTU/hr)2240021400
Heating at 47 °F(BTU/hr)2400023800
Heating at 17 °F(BTU/hr)1960023200
Heating at 5 °F(BTU/hr)2040018700

Configuration

SpecAUFITTrane
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesC-Series18 TruComfort Variable Speed Heat Pump
Indoor-Unit Combinations Rated180

Refrigerant

SpecAUFITTrane
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)