SpecDirectory

AUX AMAR09HP230V1COvsROVSUN TD-09D2HRH/DVO

Side-by-side heat pump comparison

AUX AMAR09HP230V1CO

SEER2

25BTU/Wh

HSPF2

10.5BTU/Wh

Cooling Capacity

9200BTU/hr

Cold Climate

Yes

Cold climate certified

ROVSUN TD-09D2HRH/DVO

SEER2

19.6BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

9500BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AUX AMAR09HP230V1CO is 22% more efficient at 25.0 BTU/Wh versus 19.6 BTU/Wh for the ROVSUN TD-09D2HRH/DVO. The ROVSUN TD-09D2HRH/DVO is larger at 9500 BTU/hr versus 9200 BTU/hr. ROVSUN TD-09D2HRH/DVO uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675). Overall, the AUX AMAR09HP230V1CO sits higher in the category, ranking above 89% of certified air-source heat pumps.

Efficiency

SpecAUXROVSUN
SEER2 (best combination)(BTU/Wh)2519.6
SEER2 (worst combination)(BTU/Wh)2519.6
HSPF2 (best combination)(BTU/Wh)10.510
HSPF2 (worst combination)(BTU/Wh)10.510
EER2 (best combination)(BTU/Wh)13.612
COP at 5 °F1.901.85

Capacity

SpecAUXROVSUN
Cooling Capacity (max)(BTU/hr)92009500
Cooling Capacity (min)(BTU/hr)92009500
Heating at 47 °F(BTU/hr)100009500
Heating at 17 °F(BTU/hr)94008400
Heating at 5 °F(BTU/hr)95007400

Configuration

SpecAUXROVSUN
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesC-SeriesDUCT-single
Indoor-Unit Combinations Rated11

Refrigerant

SpecAUXROVSUN
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons