SpecDirectory

Bestcold MYORU48NA22BCH18ESvsZERO ZOV-48HDTB

Side-by-side heat pump comparison

Bestcold MYORU48NA22BCH18ES

SEER2

18BTU/Wh

HSPF2

8.8BTU/Wh

Cooling Capacity

48000BTU/hr

Cold Climate

Yes

Cold climate certified

ZERO ZOV-48HDTB

SEER2

18BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

47000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

The Bestcold MYORU48NA22BCH18ES is larger at 48000 BTU/hr versus 47000 BTU/hr. ZERO ZOV-48HDTB uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecBestcoldZERO
SEER2 (best combination)(BTU/Wh)1818
SEER2 (worst combination)(BTU/Wh)1818
HSPF2 (best combination)(BTU/Wh)8.88.5
HSPF2 (worst combination)(BTU/Wh)8.88.5
EER2 (best combination)(BTU/Wh)11.29
COP at 5 °F2.101.80

Capacity

SpecBestcoldZERO
Cooling Capacity (max)(BTU/hr)4800047000
Cooling Capacity (min)(BTU/hr)4800047000
Heating at 47 °F(BTU/hr)4800047000
Heating at 17 °F(BTU/hr)2980035000
Heating at 5 °F(BTU/hr)3520033000

Configuration

SpecBestcoldZERO
Product TypeHP - Single PackageHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesGable SeriesZ-MAX
Indoor-Unit Combinations Rated11

Refrigerant

SpecBestcoldZERO
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)