SpecDirectory

BOREAL BRS36HPJ132OAvsHaier 4U36EH2HD**

Side-by-side heat pump comparison

BOREAL BRS36HPJ132OA

SEER2

20BTU/Wh

HSPF2

8.5BTU/Wh

Cooling Capacity

33600BTU/hr

Cold Climate

Yes

Cold climate certified

Haier 4U36EH2HD**

SEER2

15.7–19BTU/Wh

HSPF2

8.7–9.5BTU/Wh

Cooling Capacity

33000–33400BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

BOREAL BRS36HPJ132OA is 5% more efficient at 20.0 BTU/Wh versus 19.0 BTU/Wh for the Haier 4U36EH2HD**. The BOREAL BRS36HPJ132OA is larger at 33600 BTU/hr versus 33400 BTU/hr. BOREAL BRS36HPJ132OA uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecBOREALHaier
SEER2 (best combination)(BTU/Wh)2019
SEER2 (worst combination)(BTU/Wh)2015.7
HSPF2 (best combination)(BTU/Wh)8.59.5
HSPF2 (worst combination)(BTU/Wh)8.58.7
EER2 (best combination)(BTU/Wh)129.3
COP at 5 °F22

Capacity

SpecBOREALHaier
Cooling Capacity (max)(BTU/hr)3360033400
Cooling Capacity (min)(BTU/hr)3360033000
Heating at 47 °F(BTU/hr)3400036000
Heating at 17 °F(BTU/hr)2720023600
Heating at 5 °F(BTU/hr)2440026000

Configuration

SpecBOREALHaier
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesBRISAArctic
Indoor-Unit Combinations Rated22

Refrigerant

SpecBOREALHaier
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)

More comparisons