SpecDirectory

CanAir 4C25SCH12H11vsGREE 3VIR12HP115V1AO

Side-by-side heat pump comparison

CanAir 4C25SCH12H11

SEER2

23.2–23.4BTU/Wh

HSPF2

9.5–10.4BTU/Wh

Cooling Capacity

12000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

GREE 3VIR12HP115V1AO

SEER2

25BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

12100BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

GREE 3VIR12HP115V1AO is 6% more efficient at 25.0 BTU/Wh versus 23.4 BTU/Wh for the CanAir 4C25SCH12H11. The GREE 3VIR12HP115V1AO is larger at 12100 BTU/hr versus 12000 BTU/hr. CanAir 4C25SCH12H11 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecCanAirGREE
SEER2 (best combination)(BTU/Wh)23.425
SEER2 (worst combination)(BTU/Wh)23.225
HSPF2 (best combination)(BTU/Wh)10.49
HSPF2 (worst combination)(BTU/Wh)9.59
EER2 (best combination)(BTU/Wh)1312.5
COP at 5 °F2.331.84

Capacity

SpecCanAirGREE
Cooling Capacity (max)(BTU/hr)1200012100
Cooling Capacity (min)(BTU/hr)1200012100
Heating at 47 °F(BTU/hr)1200012100
Heating at 17 °F(BTU/hr)1000010000
Heating at 5 °F(BTU/hr)77009000

Configuration

SpecCanAirGREE
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
Series4C SeriesVireo GEN2
Indoor-Unit Combinations Rated21

Refrigerant

SpecCanAirGREE
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)

More comparisons