Coleman UPC12CN23STG1vsGREE 3VIR12HP115V1AO
Side-by-side heat pump comparison
Coleman UPC12CN23STG1
SEER2
19.5–22BTU/Wh
HSPF2
9.5–10.5BTU/Wh
Cooling Capacity
12000BTU/hr
Cold Climate
Yes
Cold climate certified
GREE 3VIR12HP115V1AO
SEER2
25BTU/Wh
HSPF2
9BTU/Wh
Cooling Capacity
12100BTU/hr
Refrigerant
R-410A
GWP 2088 · Higher
Key differences
GREE 3VIR12HP115V1AO is 12% more efficient at 25.0 BTU/Wh versus 22.0 BTU/Wh for the Coleman UPC12CN23STG1. The GREE 3VIR12HP115V1AO is larger at 12100 BTU/hr versus 12000 BTU/hr. Coleman UPC12CN23STG1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the GREE 3VIR12HP115V1AO sits higher in the category, ranking above 89% of certified air-source heat pumps.
Efficiency
| Spec | Coleman | GREE |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 22 | 25 |
| SEER2 (worst combination)(BTU/Wh) | 19.5 | 25 |
| HSPF2 (best combination)(BTU/Wh) | 10.5 | 9 |
| HSPF2 (worst combination)(BTU/Wh) | 9.5 | 9 |
| EER2 (best combination)(BTU/Wh) | 12 | 12.5 |
| COP at 5 °F | 1.80 | 1.84 |
Capacity
| Spec | Coleman | GREE |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 12000 | 12100 |
| Cooling Capacity (min)(BTU/hr) | 12000 | 12100 |
| Heating at 47 °F(BTU/hr) | 12000 | 12100 |
| Heating at 17 °F(BTU/hr) | 8900 | 10000 |
| Heating at 5 °F(BTU/hr) | 12000 | 9000 |
Configuration
| Spec | Coleman | GREE |
|---|---|---|
| Product Type | HP - Mini or Multi Split | HP - Mini or Multi Split |
| Compressor Staging | Continuously variable | Continuously variable |
| Cold Climate Certified | Yes | No |
| Connected Capability | No | No |
| Series | UPAC | Vireo GEN2 |
| Indoor-Unit Combinations Rated | 3 | 1 |
Refrigerant
| Spec | Coleman | GREE |
|---|---|---|
| Type | R-454B | R-410A |
| GWP Rating | R-454B (GWP:470 | Lower GWP) | R-410A (GWP:2088) |