SpecDirectory

Coleman XH630E2S11vsGuardian RH630E2S11

Side-by-side heat pump comparison

Coleman XH630E2S11

SEER2

15.2–17BTU/Wh

HSPF2

8–8.1BTU/Wh

Cooling Capacity

28400–31000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Guardian RH630E2S11

SEER2

16–17BTU/Wh

HSPF2

8–8.1BTU/Wh

Cooling Capacity

29600–30800BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

The Coleman XH630E2S11 is larger at 31000 BTU/hr versus 30800 BTU/hr.

Efficiency

SpecColemanGuardian
SEER2 (best combination)(BTU/Wh)1717
SEER2 (worst combination)(BTU/Wh)15.216
HSPF2 (best combination)(BTU/Wh)8.18.1
HSPF2 (worst combination)(BTU/Wh)88
EER2 (best combination)(BTU/Wh)1313
COP at 5 °F2.402.40

Capacity

SpecColemanGuardian
Cooling Capacity (max)(BTU/hr)3100030800
Cooling Capacity (min)(BTU/hr)2840029600
Heating at 47 °F(BTU/hr)3000029800
Heating at 17 °F(BTU/hr)2020019800
Heating at 5 °F(BTU/hr)1640015800

Configuration

SpecColemanGuardian
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesLX SERIESLX SERIES
Indoor-Unit Combinations Rated23119

Refrigerant

SpecColemanGuardian
TypeR-454BR-454B
GWP RatingR-454B (GWP:470 | Lower GWP)R-454B (GWP:470 | Lower GWP)