Cooper&Hunter CH-RES12-115VOvsGREE 3VIR12HP115V1AO
Side-by-side heat pump comparison
Cooper&Hunter CH-RES12-115VO
SEER2
23.2BTU/Wh
HSPF2
10.4BTU/Wh
Cooling Capacity
12000BTU/hr
Refrigerant
R-454B
GWP 470 · Lower
GREE 3VIR12HP115V1AO
SEER2
25BTU/Wh
HSPF2
9BTU/Wh
Cooling Capacity
12100BTU/hr
Refrigerant
R-410A
GWP 2088 · Higher
Key differences
GREE 3VIR12HP115V1AO is 7% more efficient at 25.0 BTU/Wh versus 23.2 BTU/Wh for the Cooper&Hunter CH-RES12-115VO. The GREE 3VIR12HP115V1AO is larger at 12100 BTU/hr versus 12000 BTU/hr. Cooper&Hunter CH-RES12-115VO uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).
Efficiency
| Spec | Cooper&Hunter | GREE |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 23.2 | 25 |
| SEER2 (worst combination)(BTU/Wh) | 23.2 | 25 |
| HSPF2 (best combination)(BTU/Wh) | 10.4 | 9 |
| HSPF2 (worst combination)(BTU/Wh) | 10.4 | 9 |
| EER2 (best combination)(BTU/Wh) | 12.5 | 12.5 |
| COP at 5 °F | 2.20 | 1.84 |
Capacity
| Spec | Cooper&Hunter | GREE |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 12000 | 12100 |
| Cooling Capacity (min)(BTU/hr) | 12000 | 12100 |
| Heating at 47 °F(BTU/hr) | 12000 | 12100 |
| Heating at 17 °F(BTU/hr) | 10000 | 10000 |
| Heating at 5 °F(BTU/hr) | 7300 | 9000 |
Configuration
| Spec | Cooper&Hunter | GREE |
|---|---|---|
| Product Type | HP - Mini or Multi Split | HP - Mini or Multi Split |
| Compressor Staging | Continuously variable | Continuously variable |
| Cold Climate Certified | No | No |
| Connected Capability | No | No |
| Series | CH Series | Vireo GEN2 |
| Indoor-Unit Combinations Rated | 2 | 1 |
Refrigerant
| Spec | Cooper&Hunter | GREE |
|---|---|---|
| Type | R-454B | R-410A |
| GWP Rating | R-454B (GWP:470 | Lower GWP) | R-410A (GWP:2088) |