Daikin DH7VSA2410A*vsZERO ZSOVA-24HDMB-USHH
Side-by-side heat pump comparison
Daikin DH7VSA2410A*
SEER2
16–19BTU/Wh
HSPF2
8.5–8.8BTU/Wh
Cooling Capacity
23200BTU/hr
Cold Climate
Yes
Cold climate certified
ZERO ZSOVA-24HDMB-USHH
SEER2
18.3BTU/Wh
HSPF2
10BTU/Wh
Cooling Capacity
23000BTU/hr
Cold Climate
Yes
Cold climate certified
Key differences
Daikin DH7VSA2410A* is 4% more efficient at 19.0 BTU/Wh versus 18.3 BTU/Wh for the ZERO ZSOVA-24HDMB-USHH. The Daikin DH7VSA2410A* is larger at 23200 BTU/hr versus 23000 BTU/hr. ZERO ZSOVA-24HDMB-USHH uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).
Efficiency
| Spec | Daikin | ZERO |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 19 | 18.3 |
| SEER2 (worst combination)(BTU/Wh) | 16 | 18.3 |
| HSPF2 (best combination)(BTU/Wh) | 8.8 | 10 |
| HSPF2 (worst combination)(BTU/Wh) | 8.5 | 10 |
| EER2 (best combination)(BTU/Wh) | 11 | 11.7 |
| COP at 5 °F | 2 | 1.87 |
Capacity
| Spec | Daikin | ZERO |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 23200 | 23000 |
| Cooling Capacity (min)(BTU/hr) | 23200 | 23000 |
| Heating at 47 °F(BTU/hr) | 23200 | 24000 |
| Heating at 17 °F(BTU/hr) | 15800 | 20800 |
| Heating at 5 °F(BTU/hr) | 17000 | 21600 |
Configuration
| Spec | Daikin | ZERO |
|---|---|---|
| Product Type | HP - Split System | HP - Split System |
| Compressor Staging | Continuously variable | Continuously variable |
| Cold Climate Certified | Yes | Yes |
| Connected Capability | Yes | No |
| Series | DH7VSA | ZAVA Series |
| Indoor-Unit Combinations Rated | 90 | 1 |
Refrigerant
| Spec | Daikin | ZERO |
|---|---|---|
| Type | R-32 | R-454B |
| GWP Rating | R-32 (GWP:675 | Lower GWP) | R-454B (GWP:470 | Lower GWP) |