SpecDirectory

Daikin DHH0601********A*vsWEATHERMAKER PH8TAN560**AA*

Side-by-side heat pump comparison

Daikin DHH0601********A*

SEER2

16.4BTU/Wh

HSPF2

7.7BTU/Wh

Cooling Capacity

60000BTU/hr

Refrigerant

R-32

GWP 675 · Lower

WEATHERMAKER PH8TAN560**AA*

SEER2

16–17.5BTU/Wh

HSPF2

8–8.5BTU/Wh

Cooling Capacity

54000–58000BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

WEATHERMAKER PH8TAN560**AA* is 6% more efficient at 17.5 BTU/Wh versus 16.4 BTU/Wh for the Daikin DHH0601********A*. The Daikin DHH0601********A* is larger at 60000 BTU/hr versus 58000 BTU/hr. WEATHERMAKER PH8TAN560**AA* uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecDaikinWEATHERMAKER
SEER2 (best combination)(BTU/Wh)16.417.5
SEER2 (worst combination)(BTU/Wh)16.416
HSPF2 (best combination)(BTU/Wh)7.78.5
HSPF2 (worst combination)(BTU/Wh)7.78
EER2 (best combination)(BTU/Wh)12.213
COP at 5 °F22.34

Capacity

SpecDaikinWEATHERMAKER
Cooling Capacity (max)(BTU/hr)6000058000
Cooling Capacity (min)(BTU/hr)6000054000
Heating at 47 °F(BTU/hr)5900061500
Heating at 17 °F(BTU/hr)3500038500
Heating at 5 °F(BTU/hr)2700031800

Configuration

SpecDaikinWEATHERMAKER
Product TypeHP - Single PackageHP - Split System
Compressor StagingTwo-stageTwo-stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesDHH2-STAGE 18 SEER HP
Indoor-Unit Combinations Rated149

Refrigerant

SpecDaikinWEATHERMAKER
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)

More comparisons