SpecDirectory

Daikin DZ7TCA2410A*vsViessmann D5CURAH24AAK+KSAIC0701230

Side-by-side heat pump comparison

Daikin DZ7TCA2410A*

SEER2

17.2BTU/Wh

HSPF2

8.1–8.2BTU/Wh

Cooling Capacity

23600–24000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Viessmann D5CURAH24AAK+KSAIC0701230

SEER2

16BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

23800BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Daikin DZ7TCA2410A* is 7% more efficient at 17.2 BTU/Wh versus 16.0 BTU/Wh for the Viessmann D5CURAH24AAK+KSAIC0701230. The Daikin DZ7TCA2410A* is larger at 24000 BTU/hr versus 23800 BTU/hr. Viessmann D5CURAH24AAK+KSAIC0701230 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Daikin DZ7TCA2410A* sits higher in the category, ranking above 44% of certified air-source heat pumps.

Efficiency

SpecDaikinViessmann
SEER2 (best combination)(BTU/Wh)17.216
SEER2 (worst combination)(BTU/Wh)17.216
HSPF2 (best combination)(BTU/Wh)8.29
HSPF2 (worst combination)(BTU/Wh)8.19
EER2 (best combination)(BTU/Wh)12.510
COP at 5 °F21.98

Capacity

SpecDaikinViessmann
Cooling Capacity (max)(BTU/hr)2400023800
Cooling Capacity (min)(BTU/hr)2360023800
Heating at 47 °F(BTU/hr)2320025400
Heating at 17 °F(BTU/hr)1400019400
Heating at 5 °F(BTU/hr)1100019800

Configuration

SpecDaikinViessmann
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesDZ7TCCrossover Heat Pump
Indoor-Unit Combinations Rated111

Refrigerant

SpecDaikinViessmann
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons