SpecDirectory

Daikin RX09BXVJUvsDaikin RXTH09AVJU*

Side-by-side heat pump comparison

Daikin RX09BXVJU

SEER2

20BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

8900BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Daikin RXTH09AVJU*

SEER2

21BTU/Wh

HSPF2

10.2BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Daikin RXTH09AVJU* is 5% more efficient at 21.0 BTU/Wh versus 20.0 BTU/Wh for the Daikin RX09BXVJU. The Daikin RXTH09AVJU* is larger at 9000 BTU/hr versus 8900 BTU/hr. Daikin RXTH09AVJU* uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecDaikinDaikin
SEER2 (best combination)(BTU/Wh)2021
SEER2 (worst combination)(BTU/Wh)2021
HSPF2 (best combination)(BTU/Wh)1010.2
HSPF2 (worst combination)(BTU/Wh)1010.2
EER2 (best combination)(BTU/Wh)12.512.2
COP at 5 °F1.801.80

Capacity

SpecDaikinDaikin
Cooling Capacity (max)(BTU/hr)89009000
Cooling Capacity (min)(BTU/hr)89009000
Heating at 47 °F(BTU/hr)1000010900
Heating at 17 °F(BTU/hr)62008000
Heating at 5 °F(BTU/hr)580010900

Configuration

SpecDaikinDaikin
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesDaikin OTERRASEER21
Indoor-Unit Combinations Rated11

Refrigerant

SpecDaikinDaikin
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons