SpecDirectory

Daikin RX09BXVJUvsMDV MOX230-09HFN10-B1

Side-by-side heat pump comparison

Daikin RX09BXVJU

SEER2

20BTU/Wh

HSPF2

10BTU/Wh

Cooling Capacity

8900BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

MDV MOX230-09HFN10-B1

SEER2

24.5–25.5BTU/Wh

HSPF2

10–10.7BTU/Wh

Cooling Capacity

9000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

MDV MOX230-09HFN10-B1 is 22% more efficient at 25.5 BTU/Wh versus 20.0 BTU/Wh for the Daikin RX09BXVJU. The MDV MOX230-09HFN10-B1 is larger at 9000 BTU/hr versus 8900 BTU/hr. MDV MOX230-09HFN10-B1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the MDV MOX230-09HFN10-B1 sits higher in the category, ranking above 92% of certified air-source heat pumps.

Efficiency

SpecDaikinMDV
SEER2 (best combination)(BTU/Wh)2025.5
SEER2 (worst combination)(BTU/Wh)2024.5
HSPF2 (best combination)(BTU/Wh)1010.7
HSPF2 (worst combination)(BTU/Wh)1010
EER2 (best combination)(BTU/Wh)12.515
COP at 5 °F1.802.23

Capacity

SpecDaikinMDV
Cooling Capacity (max)(BTU/hr)89009000
Cooling Capacity (min)(BTU/hr)89009000
Heating at 47 °F(BTU/hr)1000010000
Heating at 17 °F(BTU/hr)62009400
Heating at 5 °F(BTU/hr)58007300

Configuration

SpecDaikinMDV
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesDaikin OTERRAMSEP Series
Indoor-Unit Combinations Rated14

Refrigerant

SpecDaikinMDV
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)